1001 and 1002 alarm on GSK 980TD CNC Controller
Paycnc.com - PAY for CNC components
1001 and 1002 alarm on GSK 980TD CNC Controller
GSK980TD CNC Operator:
GSK980TD has a problem during the tool change: the alarm number 1001, 1002 always appears from time to time, how can the master solve it? Thank you?

CNCmakers Support:
It is caused by incorrect tool position. It may be that there is iron filings under the tool post which causes the rotation of the tool post to be blocked; or it is possible that the indexing is incorrect due to the loosening of the fastening screws of the signal plate of the tool post.
The solution is to first remove the iron filings under the tool holder and change the tool position to see if it alarms; if it does not work, open the protective cover of the signal plate, correct the position of the signal plate, and then tighten its two fastening screws, using a 2.5 internal hexagonal wrench .
TOP
Message Us