GSK988TA1 alarms after change GS2000 Servo Driver
Paycnc.com - PAY for CNC components
GSK988TA1 alarms after change GS2000 Servo Driver
After replacing the GS2000 AC Servo Driver, matching parameters is the key to resolving alarms.

Detail Video on Youtube

Alarm troubleshooting: A loop error occurred after replacing the GS2000 servo drive; inspection revealed a duplicate communication address, as both devices were set to Station No. 3, causing a conflict.
Address correction: By adjusting parameter PA156, the X-axis communication address was changed back to Station No. 1; the device was restarted after saving, and the loop error was cleared.
Parameter configuration: For the GSK988TA1 cnc system, the manufacturer password (xxxxxx) is required to modify parameter 1815 and set the reference point; subsequently, the electronic gear ratio must be adjusted to match the replacement drive. All alarm notifications on the device have now been cleared.

Operation begins: The GS2000 drive was damaged; a loop error was reported after installing the new drive. 00:00

Troubleshooting: An address conflict was found; checking communication settings revealed two "Station No. 3" entries, while the X-axis "Station No. 1" was missing. 00:06

Adjusting parameters: Modified the communication address via parameter PA156, setting the X-axis address to 1; saved settings and power-cycled the device. 00:24

Setting the reference point: Entered the manufacturer password to modify the APZ parameter; the password "six 2s" was required to make the change. 01:07

Restarting the system: Completed parameter settings by setting APZ to 1 and restarting; no alarms remained, though the electronic gear ratio still required checking. 01:50

Paycnc offers all kinds of CNC spare parts.