Minimum unit of GSK980TDb
Q: How to select the fundamental unit of machine instruction of GSK980TDb CNC lathe control?
A: Restore the 1U and 0.1U parameter of the ex-work parameters, it requires below two conditions:
A: Restore the 1U and 0.1U parameter of the ex-work parameters, it requires below two conditions:
- AC servo motor must A2 type (5000 lines encoder)
- AC servo driver must be dual type, analog and pulse+direction.