READ CMOS MEMORY GSK983Ma
Paycnc.com - PAY for CNC components
READ CMOS MEMORY GSK983Ma

Control GSK 983 Ma-H RV2.8.2.1 User:

Dear Sirs of CNCMAKER:

I have a control GSK 983 Ma-H RV2.8.2.1 VB and does not complete the initialization..Screens showing ;

WAITING FOR TO READY

READ CMOS MEMORY

NOT READY.

Permanently maintained in NOT READY

I would need some suggestions and send me the following manuals:

- Parameters Manual for GSK983Ma-H Version RV2.8.2.1

- Commissioning / Sevice Manuals for GSK983Ma-H Version RV2.8.2.1

- Procedure for uploading parameters and PLC files.

 

CNCmakers Support:

The alarms means the CNC controller GSK983Ma has not received I/O signal.

There are two sources of I/O signal, one from the I/O unit, another from the keyboard.

So please check the wiring between GSK983Ma and I/O unit, controller to I/O unit.

and check the keyboard connection too, upper panel to lower panel.