Control GSK 983 Ma-H RV2.8.2.1 User:
Dear Sirs of CNCMAKER:
I have a control GSK 983 Ma-H RV2.8.2.1 VB and does not complete the initialization..Screens showing ;
WAITING FOR TO READY
READ CMOS MEMORY
NOT READY.
Permanently maintained in NOT READY
I would need some suggestions and send me the following manuals:
- Parameters Manual for GSK983Ma-H Version RV2.8.2.1
- Commissioning / Sevice Manuals for GSK983Ma-H Version RV2.8.2.1
- Procedure for uploading parameters and PLC files.
CNCmakers Support:
The alarms means the CNC controller GSK983Ma has not received I/O signal.
There are two sources of I/O signal, one from the I/O unit, another from the keyboard.
So please check the wiring between GSK983Ma and I/O unit, controller to I/O unit.
and check the keyboard connection too, upper panel to lower panel.